Hafnium (Hf) X-ray absorption edges

The Hf K edge is at 65,351 eV. The tables list 19 absorption edges for hafnium; K, L1​, L2​, L3​, M1​, M2​, M3​, M4​, M5​, N1​, N2​, N3​, N4​ and N5​ lie between 100 eV and 100 keV, the range the lab can scan.

Atomic number
Z=72
Molar mass
178.49 g/mol
Edges in the lab range
14 of 19

Open hafnium in the lab

Both load hafnium as a pure sample with the formula Hf. Density is retained from your current settings because these X-ray tables have no density. Enter your sample's density on the Sample page before planning a thickness. To scan another edge, use the links in the table below.

Absorption edges of hafnium

Energies, jump ratios and fluorescence yields as tabulated by Elam, Ravel and Sieber (2002). Scroll within the table to see every column.
EdgeEnergy (eV)Jump ratioFluorescence yieldIn the lab
K65,3515.1850.98232ScanHard X-ray
L1​11,2711.154390.128ScanHard X-ray
L2​10,7391.40.246ScanHard X-ray
L3​9,5612.630.231ScanHard X-ray
M1​2,6011.040.00135ScanHard X-ray
M2​2,3651.0580.0024167ScanHard X-ray
M3​2,1071.15480.00198ScanHard X-ray
M4​1,7161.1440.011533ScanSoft X-ray
M5​1,6621.2550.018633ScanSoft X-ray
N1​5381.074220.000057ScanSoft X-ray
N2​438.21.0050.000071667ScanSoft X-ray
N3​380.71.0810.000056667ScanSoft X-ray
N4​2201.020.00010333ScanSoft X-ray
N5​211.51.0370.00011ScanSoft X-ray
N6​15.910.0000024Outside range
N7​14.210.0000024Outside range
O1​64.210Outside range
O2​3810Outside range
O3​29.910Outside range

Jump ratio is the photoabsorption just above the edge divided by the photoabsorption just below it. Fluorescence yield is the probability that a core hole in that shell decays by emitting an X-ray. Both are dimensionless. The lab can scan across edges strictly between 100 eV and 100 keV; other edges are listed for reference. A listed edge with jump ratio 1 has no step for thickness planning.

Transmission, fluorescence or electron yield

K, L1​, L2​, L3​, M1​, M2​ and M3​ are hard X-ray edges in the lab's classification (2 keV and above). The sample planner suggests transmission when the edge step is large enough relative to total attenuation. For a small step, as in a dilute absorber, it suggests fluorescence. Concentration alone does not decide the measurement mode.

M4​, M5​, N1​, N2​, N3​, N4​ and N5​ are soft X-ray edges in the lab's classification (below 2 keV). Transmission generally needs thin films or membranes, so the planner suggests fluorescence or electron yield. The fluorescence yield at M4​, M5​, N1​, N2​, N3​, N4​ and N5​ is below 0.05, where the lab suggests considering total electron yield.

These are planning rules of thumb. Sample thickness, self-absorption and the beamline's energy range and detectors still matter. The lab simulates transmission; it does not simulate fluorescence or electron-yield detector counts.

Values from XrayDB 9.2 (Elam, Ravel and Sieber, 2002), released into the public domain. These isolated-atom tables do not include chemical shifts, XANES or EXAFS fine structure. Methods and data sources