Francium (Fr) X-ray absorption edges
The Fr L3 edge is at 15,031 eV. The tables list 24 absorption edges for francium; L1, L2, L3, M1, M2, M3, M4, M5, N1, N2, N3, N4, N5, N6, N7, O1, O2 and O3 lie between 100 eV and 100 keV, the range the lab can scan.
- Atomic number
- Z=87
- Molar mass
- 223 g/mol
- Edges in the lab range
- 18 of 24
Open francium in the lab
Both load francium as a pure sample with the formula Fr. Density is retained from your current settings because these X-ray tables have no density. Enter your sample's density on the Sample page before planning a thickness. To scan another edge, use the links in the table below.
Absorption edges of francium
| Edge | Energy (eV) | Jump ratio | Fluorescence yield | In the lab |
|---|---|---|---|---|
| K | 101,137 | 4.481 | 0.97227 | Outside range |
| L1 | 18,639 | 1.15688 | 0.13 | ScanHard X-ray |
| L2 | 17,907 | 1.4 | 0.443 | ScanHard X-ray |
| L3 | 15,031 | 2.443 | 0.424 | ScanHard X-ray |
| M1 | 4,652 | 1.04 | 0.004095 | ScanHard X-ray |
| M2 | 4,327 | 1.058 | 0.010812 | ScanHard X-ray |
| M3 | 3,663 | 1.16056 | 0.00675 | ScanHard X-ray |
| M4 | 3,136 | 1.555 | 0.041325 | ScanHard X-ray |
| M5 | 3,000 | 3.135 | 0.039575 | ScanHard X-ray |
| N1 | 1,153 | 1.017 | 0.0004225 | ScanSoft X-ray |
| N2 | 980 | 1.005 | 0.0003175 | ScanSoft X-ray |
| N3 | 810 | 1.06 | 0.0002025 | ScanSoft X-ray |
| N4 | 603 | 1.02 | 0.0003275 | ScanSoft X-ray |
| N5 | 577 | 1.124 | 0.0003275 | ScanSoft X-ray |
| N6 | 268 | 1.287 | 0.000445 | ScanSoft X-ray |
| N7 | 268 | 1.287 | 0.000445 | ScanSoft X-ray |
| O1 | 234 | 1.3 | 0 | ScanSoft X-ray |
| O2 | 182 | 1.16 | 0 | ScanSoft X-ray |
| O3 | 140 | 1.5 | 0 | ScanSoft X-ray |
| O4 | 58 | 1 | 0 | Outside range |
| O5 | 58 | 1 | 0 | Outside range |
| P1 | 24 | 1 | 0 | Outside range |
| P2 | 14 | 1 | 0 | Outside range |
| P3 | 7 | 1 | 0 | Outside range |
Jump ratio is the photoabsorption just above the edge divided by the photoabsorption just below it. Fluorescence yield is the probability that a core hole in that shell decays by emitting an X-ray. Both are dimensionless. The lab can scan across edges strictly between 100 eV and 100 keV; other edges are listed for reference. A listed edge with jump ratio 1 has no step for thickness planning.
Transmission, fluorescence or electron yield
L1, L2, L3, M1, M2, M3, M4 and M5 are hard X-ray edges in the lab's classification (2 keV and above). The sample planner suggests transmission when the edge step is large enough relative to total attenuation. For a small step, as in a dilute absorber, it suggests fluorescence. Concentration alone does not decide the measurement mode.
N1, N2, N3, N4, N5, N6, N7, O1, O2 and O3 are soft X-ray edges in the lab's classification (below 2 keV). Transmission generally needs thin films or membranes, so the planner suggests fluorescence or electron yield. The fluorescence yield at N1, N2, N3, N4, N5, N6, N7, O1, O2 and O3 is below 0.05, where the lab suggests considering total electron yield.
These are planning rules of thumb. Sample thickness, self-absorption and the beamline's energy range and detectors still matter. The lab simulates transmission; it does not simulate fluorescence or electron-yield detector counts.
Values from XrayDB 9.2 (Elam, Ravel and Sieber, 2002), released into the public domain. These isolated-atom tables do not include chemical shifts, XANES or EXAFS fine structure. Methods and data sources